Pro-RF AAPM 15

02-117

This Digital Subtraction Angiography (DSA) Phantom follows the recommendation in Report No. 15 by the AAPM (American Associationof Physicists in Medicine) - Digital Radiology / Fluorography Task Group of the Diagnostic X-Ray Imaging Committee. Phantom is designed toevaluate digital functions of DSA systems and can be used to check: contrast range, resolution, linearity, uniformity, amplifier dynamic range,registration accuracy and subtraction effectiveness. Its modular construction allows setting up the desired test configuration in a very easy andaccurate manner.

Technical data (can be modified to customer specifications):

Section I and II

A 6-step wedge made of sanded transparent plastic.

Step Wedge module, 6 step wedges (each 25.4 mm high) to test dynamic range. Can be folded into 203.2 x 203.2 x 76.5 mm solid block.

Section III

A square block made of transparent sanded plastic with a hole to fit other modules.

Slot block with a space to fit other test modules.
Outer size: 203.2 x 203.2 x 76.5 mm.
Slot size: 203.2 x 152.4 x 25.4 mm.

Registration plate

A square aluminium plate with bevelled corners and an array of holes on the whole surface.

Made of aluminium with an array of 3.18 mm holes.
Size: 203.2 x 203.2 x 1.5 mm

Bone section

A square object made of sanded transparent plastic with embedded 3 Teflon stripes.

With three PTFE strips 25 mm in width and 5, 10 and 15 mm in thickness.
Size: 203.2 x 203.2 x 25.4 mm

High Contrast Resolution Section

A rectangular block made of sanded transparent plastic with a square hole in the middle for inserting a resolution plate.

Containing pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm).
Thanks to the dedicated recesses, test pattern can be placed in different orientations.
Size: 203.2 x 203.2 x 25.4 mm

Blank insert

A rectangular block made of sanded transparent plastic.

Used with other modules forms a mask plate.
Size: 203.2 x 152.4 x 25.4 mm

Linearity Insert

A rectangular block made of sanded transparent plastic.

Contains 6 iodine areas (19 mm diameter) of different iodine thickness and concentration: 0.5, 1.0, 2.0, 4.0, 10.0 and 20.0 mg/cm².
Size: 203.2 x 152.4 x 25.4 mm

Low Contrast Artery Insert

A rectangular block made of sanded transparent plastic.

Containing 3 sets of analogue blood vessel group (diameters 0.5, 1.0, 2,0 and 4.0 mm), each vessels group includes different iodine concentrations: 2.5, 5.0 and 10.0 mg/cc.
Size: 203.2 x 152.4 x 25.4 mm

150 mg/ml Iodine Artery Insert

A rectangular block made of sanded transparent plastic.

3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctial and arterial aneurysm whose sizes are 1/4, 1/2 and 3/4 of artery diameter.
Size: 203.2 x 152.4 x 25.4 mm

300 mg/ml Iodine Artery Insert

A rectangular block made of sanded transparent plastic.

3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctia and arterial aneurysm whose sizes are 1/4, 1/2 and 3/4 of artery diameter.
Size: 203.2 x 152.4 x 25.4 mm

Carrying Case

Product features:

  • complies with:
    – AAPM Report No. 15 - Performance Evaluation and Quality Assurance in Digital Subtraction Angiography - Diagnostic X-Ray Imaging Committee Digital Radiography / Fluorography Task Group - May 1985
    – IEC 61223-3-1
  • CE certified
  • the manual provides detailed guidelines for carrying out each test, results assessment and registration

Ask a Distributor for an offer

Locate a local distributor and access exclusive medical offers tailored to your needs.

Share this product
Close Cookie Preference Manager
Cookie Settings
By clicking “Accept All Cookies”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage and assist in our marketing efforts. More info
Strictly Necessary (Always Active)
Cookies required to enable basic website functionality.
Made by Flinch 77
Oops! Something went wrong while submitting the form.